SKU: ADC-AC-X1100-4PSE
Specifications
Controller specifications: The interface is for use only in low-voltage, Class 2 circuits.
The installation of this device must comply with all local fire and electrical codes.
Input power: 12 to 24 VDC ±10%, 1.9 A max (Controller); 12 to 24 VDC ±10%, 1.5 A max (Expansion Module) Output power: 12 VDC ±10%, 500 mA max each reader
Communication: Shielded 2-wire RS-485 Inputs per device: Two dedicated reader inputs, our programmable inputs, One dedicated input for each of the following: Tamper, AC Fail, and Battery Fail Outputs per device: Four relay outputs 5 A (NO) and 3 A (NC) @ 30 VDC, Two-wire LED control, Single-wire buzzer output Certifications: FCC, CE, UL 294 certified (Controller); UL 294 recognized, CE compliant, FCC Class A, ICES-003 (Expansion Module) Dimensions (W x L x H): 6.46 x 5.51 x 1.02” (16.4 x 14.0 x 2.6 cm)
Temperature: 32°F to 158°F (0°C to 70°C) operational, -67°F to 185°F (-55°C to 85°C) storage
Operating humidity: 5% to 85% (noncondensing) RH Kit Specifications Dimensions: 20 x 16 x 4.5" (50.8 x 40.64 x 11.43 cm)
Weight: 26 lbs. (11.8 kg)