NAPCO Integrated Fire Alarm Control Panel & Cellular Communicator FL-32FACP-LTEVS

Brand: Napco

$0.00

Product Overview:

NAPCO Integrated Fire Alarm Control Panel & Cellular Communicator FL-32FACP-LTEVS

Key Features:

• Lowest Equipment Cost Available for Any Full-Featured Cellular Reporting Fire Alarm Solution

• Saves Both Installation Time & Money

  • Sole Path Communicators

• Award-Winning All-in-One Design - Cellular Alarm Reporting, with choice
of Nation’s two largest multibillion-dollar cyber-protected networks
• Proven NAPCO StarLink Fire® Sole Path Cell High-Performance Dual Diversity
Twin Antennas & Signal Boost™ Circuitry for greater range & reliability
(Cell/IP models also available)
• Powerful FACP with 8 Conventional Points, preprogrammed
• Cloud-based or Software Option for Custom PC programming:
Expandable up to 32 Points, including Conventional
or Addressable Devices
• Powerful 4A Onboard Power Supply
• NFPA & UL Code Compliant

FIRELINK SYSTEM SPECIFICATIONS:
• FACP: 8 to 32 Zone Conventional Fire Alarm Control Panel,
8 conventional fire zones, suitable for 2-wire fire, expandable to 32;
2 programmable NAC circuits, 2A max @ 24V
• Annunciator: Menu-driven operation with backlit custom alphanumeric
display and functionality for Reset, Acknowledge, Silence (with disable).
• Sole Path LTE Cellular Communicator, Commercial Fire (StarLink Fire®)
Onboard: Reports on choice of 2 of Nation’s largest multibillion dollar,
cyberprotected networks, for maximum security & liability protection,
code-compliant, replaces 2 POTS lines
• Reports to any Central Station, via dial up or IP, without any
special equipment.
• Integrated sync and smart operation support on each NAC for
System Sensor™ and Wheelock® Notification Devices
• Power Supply, 4A @ 24V
• Regulated Auxiliary Power Supply – Commercial fire, 12V regulated 2A
• 2 Onboard serial ports – one for high-speed local downloading
• New! Fully Cloud Programmable, Preprogrammed, or optional Quickloader®
Software custom programmable.
• Conveniently Preprogrammed –
Default Program
• Locking Enclosure for surface mount* or recess mounting
(between the studs) 16”x 14.25” x 5.2” (H x W x D) without cover.
Houses up to 16Ah @ 24V battery backup capacity. * Note: For flush mount
applications, use external antennas (see ordering info.)
• 36-Month Napco Warranty
FACP EXPANSION OPTIONS
• Expandable with conventional or SLC addressable devices
• Main FACP board supports 1 Addressable Fire SLC (addressable
Signaling Line Circuit controllers)
• Fire 4-wire bus for annunciators and non-SLC (conventional) devices,
including 12V devices
• Supports up to 6 additional Red fire annunciators, GEMC-FK1 or FireLink FLFK1, mounted anywhere on the bus (flashable/updatable firmware)
• Addressable SLC Loop Isolator (optional use - for fire applications requiring
increased circuit integrity, e.g., meets Class A, Style 7 loop requirements.
• SLC Fire Devices supported: Analog smoke detector, analog heat detector,
duct detector, pull station, conventional zone module & short circuit isolator
FACP INPUTS
• Up to 32 Zones/Points from a wide range of initiating devices
(see ordering info.)
• Addressable SLC Loop – supports up to 1, 32 point loop
• Conventional 1- to 4-zone EZM Expansion modules on the 4-wire fire bus
or SLC loops
• Conventional 2-wire or 4-wire smoke detector inputs
• SLC Fire Devices supported: analog smoke detector, analog heat detector,
duct detector, pull station, conventional zone module & short circuit isolator
FACP OUTPUTS
• Up to 96 outputs
• Two onboard Class B or 1 Class A NAC circuits, 2 amps each,
total 2A @ 24V
• Onboard Wheelock and System Sensor NAC sync/strobe/horn protocol
allows initial silence of audible appliances while maintaining visual
notification, without the use of additional modules
• Addressable SLC Fire Devices: Supervised relay, unsupervised relay
• Fire 4-wire bus devices: 8 zone form C relay (GEMC-RM3008),
8 open collector output (GEMC-OUT8)
• Support for Legacy and Existing Notification Appliances – One NAC
output configurable for 12V for easy retrofit compatibility
• UL Regulated NAC output
• Automatic drift compensation for SLC smoke detectors
• Programmable obscuration level by smoke detector device
• Tri-Mode Smoke Obscuration Report (for addressable detectors)
generated remotely or locally (see WI2309LF instructions)

 

(3 products available)
Quantity

SKU: FL-32FACP-LTEVS

Categories: Fire, Control Panel

Specifications

  • Combination FACP / Commercial Fire Cellular Communicator.
  • Supports 8 conventional zones, expandable to 32 through analog addressable, wireless and conventional fire devices.
  • 2 programmable NAC circuits, 2A each @ 24V.
  • Fire annunciator on door, support for up to 6 additional remote annunciators.
  • No programming required, pre-programmed with sprinkler supervisory / basic fire program. Advanced programming Over The Air
  • using NAPCO QuickLoader.
  • System is completely prewired and assembled, just mount on wall,
  • connect AC, ground, initiating and indicating devices and it is ready to go.
  • Lowest Equipment Cost Available for Any Full-Featured Cell Reporting Fire Alarm Solution
  • Saves Both Installation Time & Money

0.00

5 Star
0%
4 Star
0%
3 Star
0%
2 Star
0%
1 Star
0%

Submit Your Review

Please login to write review!

Upload photos
You can upload up to 6 photos, each photo maximum size is 2048 kilobytes