Napco StarLink Max Fire Dual Path Commercial Fire/Burglar SLE-MAXVI-FIRE

Brand: Napco

$0.00

Product Overview:

Product Details

The SLE-MAXVI-FIRE and SLE-MAXAI-FIRE Sole/Dual-Path Alarm Communicators are specifically designed to interface with FACP (Fire Alarm Control Panels) and to comply with UL 864. The SLE-MAXVI-FIRE operates on the Verizon network, the SLE-MAXAI-FIRE on the AT&T network and both models utilize CAT-M1 technology. These devices support both Sole Path and dual-path communication. Sole Path communication is cellular only and Dual Path communication is cellular and IP, which requires connection to the local network using the on-board Ethernet jack or via Wi-Fi using the optional UL 864 Certified SLE-WIFI-MODULE.

 

(Available)
Quantity

SKU: SLE-MAXVI-FIRE

Specifications

Specifications

Electrical Ratings for +12V / 24V (powered by the control panel)†

  • Input Voltage - 10-24VDC regulated (power-limited output from Certified control panel Aux/Remote Fire Power)
  • Input Current - 10VDC standby: 115mA, 12VDC standby: 101mA, 15VDC standby: 92mA, 24VDC standby: 85mA
  • Wi-Fi Module - (Optional) Add 45mA to the above. (With peak RF transmission current of 325mA)

Electrical Ratings for the IN 1 Fire Input

  • Input Voltage - 9-25VDC
  • Maximum Input Current - Up to 2mA from FACP NAC circuit

Electrical Ratings for IN 2, IN 3, IN 4, and IN 5: (Inputs IN 2, IN 3, IN 4, and IN 5 are Class B)

  • Maximum Loop Voltage - 25VDC input
  • Maximum Loop Current - 1.7mA
  • End of Line Resistor (EOLR) Value - 10K

Electrical Ratings for PGM3 Output

  • Open Collector Output - Maximum Voltage 25VDC
  • Maximum PGM Sink Current - 50mA (up to 15VDC), 25mA (15.1VDC - 25VDC)

Physical (W x H x D)

  • Plastic Housing - 8 x 5-29/64 x 1½" (20.3 x 13.9 x 3.8cm)
  • Mounting - Plastic housing includes three keyhole slots for triple gang boxes
  • Antenna Length - 8.25" (21cm)

Environmental

  • Operating Temperature - 0°C - 49°C (32°F - 120°F)
  • Humidity - Maximum 93% Non-Condensing
  • Environment - Indoor/dry location use only

SKU: SLE-MAXI-FIRE
UL985 Household Fire Warning System
UL864 10th Edition Control Units For Fire Alarm Systems Powered by Control Panel
Input: 12-24VDC (100mA @ 24VDC w/peak RF transmission draw of 200mA)
Also includes: (4) Programmable EOLR Zone inputs for connection to legacy FACPs
(2) Form C relay outputs, eliminating the need for additional listed supervision relay
(2) Modular RJ45 Telco jacks for easy connection to FACP

0.00